Cost Factors ($FY05)
Inventory records
Construction
Sustainment
Upper limit
Reset
Code
Title
UM
Type
Description
Value
Construction Material
||content||
,466,928.75
,352.98
1
1
A facility for the production of construction materials for the installation. Cost factors are
2291
EA
S
based upon a 250-TN/Hr commercial production plant. CCF is derived from Marshall &
Production Plant
Swift data. SCF is based on the ratio for FAC 2261.
RDT&E Laboratory
9.72
.73
1,000,000
3,500
Buildings used directly in theoretical or applied research, development, testing, and
3101
SF
B
evaluation activities. CCF is derived from USACE data. SCF is derived from a DoD
developed template based on the DoD average size of 14,136 SF, and run through the
Whitestone MARS model.
Medical Research
7.30
.23
1,000,000
3,500
Buildings used directly in theoretical or applied research, development, testing, and
3102
SF
B
evaluation activities for medical research. CCF is derived from Army data. SCF is derived
Laboratory
using a DoD developed template and running it through the Whitestone MARS.
Aircraft RDT&E
9.72
.45
500,000
4,000
Buildings used in the direct research, development, testing, and evaluation of airframes and
3111
SF
B
other related assemblies, spares, and aircraft equipment. CCF is derived from USACE data.
Facility
SCF is derived from a DoD developed template based on the DoD average size of 19,455
SF, and run through the Whitestone MARS model.
Missile and Space
4.43
.13
400,000
4,000
Buildings used in the direct research, development, testing, and evaluation of missiles,
3121
SF
B
missile systems, related ground handling and launching equipment, and other aerospace
RDT&E Facility
equipment. CCF is derived from AFCESA data. SCF is derived from a DoD developed
template based on the DoD average size of 11,200 SF, and run through the Whitestone
MARS model.
Ship and Marine
6.16
.55
500,000
8,000
Buildings used in the direct research, development, testing, and evaluation of ships and
3131
SF
B
marine equipment, and amphibious vehicles. CCF is derived from RS Means data. SCF is
RDT&E Facility
derived from a DoD developed template based on the DoD average size of 25,350 SF, and
run through the Whitestone MARS model.
Tank and Automotive
7.97
.67
120,000
6,000
Buildings used in the direct research, development, testing, and evaluation of tank and other
3141
SF
B
automotive equipment. CCF is derived from USACE data. SCF is derived from a DoD
RDT&E Facility
developed template based on the DoD average size of 15,142 SF, and run through the
Whitestone MARS model.
Weapons RDT&E
4.43
.11
150,000
2,500
Buildings used in the direct research, development, testing, and evaluation of weapons and
3151
SF
B
weapon systems. Does not include missile-related research under Facility Analysis Category
Facility
3121. CCF is derived from AFCESA data. SCF is derived from a DoD developed template
based on the DoD average size of 8,276 SF, and run through the Whitestone MARS model.
9.72
.98
450,000
1,500
Buildings used in the direct research, development, testing, and evaluation of ammunition,
3161
SF
B
explosives, and toxic materials. CCF is derived from USACE data. SCF is derived from a
Explosive, and Toxic
DoD developed template based on the DoD average size of 3,411 SF, and run through the
RDT&E Facility
Whitestone MARS model.
Electronic and
9.72
.69
650,000
2,200
Buildings used in the direct research, development, testing, and evaluation of electronic and
3171
SF
B
communication equipment. CCF is derived from USACE data. SCF is derived from a DoD
Communication
developed template based on the DoD average size of 9,384 SF, and run through the
RDT&E Facility
Whitestone MARS model.
Propulsion RDT&E
9.72
.99
200,000
2,000
Buildings used in the direct research, development, testing, and evaluation of propulsion
3181
SF
B
hardware and propellant fuels. CCF is derived from USACE data. SCF is derived from a
Facility
DoD developed template based on the DoD average size of 8,024 SF, and run through the
Whitestone MARS model.
Miscellaneous Item
7.97
.28
650,000
1,500
Buildings used in the direct research, development, testing, and evaluation of miscellaneous
3191
SF
B
items of equipment, such as clothing, survival equipment, and military engineering
and Equipment
equipment. CCF is derived from USACE data. SCF is derived from a DoD developed
RDT&E Facility
template based on the DoD average size of 6,072 SF, and run through the Whitestone
MARS model.
29
DOD FACILITIES PRICING GUIDE Version 7