36
PART 1
UFC 3-701-05
March 2005
Cost Factors ($FY05)
Inventory records
Construction
Sustainment
Upper limit
Reset
Code
Title
UM
Type
Description
Value
Drug and Alcohol
4.50
.67
35,000
3,200
A facility for counseling personnel suffering from drug or alcohol abuse. CCF is derived
7314
SF
B
from USACE data. SCF is derived from a DoD developed template based on the DoD
Abuse Center
average size of 4,812 SF, and run through the Whitestone MARS model.
Bread/Pastry Kitchen
1.37
.59
100,000
5,000
A centralized food service facility that provides fresh breads and pastries to the installation.
7321
SF
B
CCF is derived from Air Force data. SCF is derived from a DoD developed template based
on the DoD average size of 14,187 SF, and run through the Whitestone MARS model.
Ice/Dairy Products
9.93
.65
35,000
3,600
A central plant that produces or processes ice or milk products for the installation. CCF is
7322
SF
B
derived from USACE data. SCF is derived from a DoD developed template based on the
Plant
DoD average size of 2,997 SF, and run through the Whitestone MARS model.
Greenhouse
.60
15,000
1,500
A facility with glass walls and roof in which temperature and humidity can be regulated for
7323
SF
B
the growing and protection of plants. CCF is derived from RS Means data. SCF is derived
from a DoD developed template based on the DoD average size of 1,165 SF, and run
through the Whitestone MARS model.
Exchange Eating
3.18
.28
35,000
2,000
A facility that provides either self-service or counter service. These facilities are operated
7331
SF
B
by/for the exchange system and include fast-food concessions. CCF is derived from USACE
Facility
data. SCF is derived from a DoD developed template based on the DoD average size of
3,019 SF, and run through the Whitestone MARS model.
Non-Exchange Eating
3.78
.99
60,000
2,000
Eating facilities not managed by the exchange system that provide food and beverages,
7332
SF
B
served to personnel by operators who are not associated with the exchange. CCF is derived
Facility
from USACE data. SCF is derived from a DoD developed template based on the DoD
average size of 3,296 SF, and run through the Whitestone MARS model.
Open Mess and Club
7.07
.94
80,000
9,000
Open dining facilities include officer, noncommissioned officer, enlisted and civilian clubs,
7333
SF
B
that provide dining, social programs and entertainment services for the membership. CCF is
Facility
derived from USACE data. SCF is derived from a DoD developed template based on the
DoD average size of 6,349 SF, and run through the Whitestone MARS model.
Thrift Shop
9.11
.30
25,000
3,500
Thrift shops are nonprofit facilities for the sale and purchase of used goods and handmade
7340
SF
B
items. Volunteer family members normally operate these facilities on a consignment basis.
CCF is derived from USACE data. SCF is derived from a DoD developed template based
on the DoD average size of 4,017 SF, and run through the Whitestone MARS model.
Bus Station
2.47
.91
12,000
100
A facility for personnel to purchase tickets and await bus service. This does not include a
7341
SF
B
simple enclosed bus stop that is under Facility Analysis Category 7384. CCF is derived from
RS Means data. SCF is derived from a DoD developed template based on the DoD average
size of 6,000 SF, and run through the Whitestone MARS model.
Laundry/Dry Cleaning
1.21
.92
60,000
2,000
Laundry and dry cleaning facilities provide large-scale laundry and/or dry cleaning
7342
SF
B
operations at most installations or are used at installations for washing protective gear and
Facility
operators clothing for industrial operations. CCF is derived from USACE data. SCF is
derived from a DoD developed template based on the DoD average size of 5,487 SF, and
run through the Whitestone MARS model.
Clothing Sales Store
9.11
.85
35,000
4,200
A facility for the sales of military clothing and personal equipment. CCF is derived from
7343
SF
B
USACE data. SCF is derived from a DoD developed template based on the DoD average
size of 5,713 SF, and run through the Whitestone MARS model.
Postal Facility
2.16
.52
50,000
2,000
A facility that houses United States Postal Service operations. CCF is derived from RS
7344
SF
B
Means data. SCF is derived from a DoD developed template based on the DoD average size
of 3,485 SF, and run through the Whitestone MARS model.