Cost Factors ($FY05)
Inventory records
Construction
Sustainment
Upper limit
Reset
Code
Title
UM
Type
Description
Value
Miscellaneous Paved
.24
||content||
.24
4,700,000
200
Paved surfaces that are not included in another Facility Analysis Category. CCF is derived
8526
SY
S
from USACE data. SCF is derived from RS Means data.
Area
Parking
.95
1,140,000
100,000
A structure or building for parking private and/or government owned vehicles and equipment
8531
SF
S
in individual parking spots/locations. Facility may be above-ground or underground. CCF is
Garage/Building
derived from RS Means data. SCF is derived from Whitestone Research data.
Traffic Control
,117.95
1.84
250
50
A traffic control signal consists of the various components; such as controls, controller
8541
EA
S
cabinets, light fixtures, masts, detectors, and conduits; to control vehicle and pedestrian
Signals
traffic at a single intersection. CCF is derived from data from VADOT. SCF is derived from
data from RS Means.
Railroad Track
3,002.16
,088.88
212
2.5
Rail track to include spurs, sidings, yards, and turnouts. Track includes two parallel rails,
8601
MI
S
crossties, and roadbed. CCF is derived from BNI data. SCF is derived from data provided
by various commercial railroads.
Railroad Bridge
,446.62
2.23
2,400
100
Bridges that support railroad track crossing of a river, road underpass, or similar gap. CCF is
8611
LF
S
derived from the American Segmented Bridge company data. SCF is based on the ratio for
FAC 8601.
Miscellaneous
,769.03
||content||
,848.29
1
1
A facility, other than track, normally associated with rail operations. Cost factors are based
8612
EA
S
upon a railroad scale contained within a 100' section of track. CCF is derived from Marshall
Railroad Facility
& Swift data. SCF is based on the ratio for FAC 8601.
.78
400,000
1,800
Drainage pipes or ditches intended to capture and direct the flow of storm water. CCF is
8711
LF
S
derived from Marshall & Swift (Dodge Cost Guide) data. SCF is derived from RS Means
data.
Retaining Structure
8.99
.08
26,350
220
A structure constructed to restrict or prevent the horizontal movement of earth. CCF is
8712
LF
S
derived from Marshall & Swift data. SCF is based on the ratio for FAC 8721.
Dams and Dikes
,229.80
7.65
1
1
A barrier constructed to obstruct the normal flow of a watercourse, causing the water to
8713
EA
S
back-up or divert its path of flow. CCF is derived from data provided by all the Services.
SCF is derived from RS Means data.
Fence and Wall
.39
1,400,000
1,000
A linear structure intended to restrict access to a specific area or to restrict and direct the flow
8721
LF
S
of traffic. CCF is derived from USACE data. SCF is derived from RS Means data.
Utility Building
1.21
.13
800,000
300
A building that contains utility equipment and functions. CCF is derived from USACE data.
8910
SF
B
SCF is derived from a DoD developed template based on the DoD average size of 1,297 SF,
and run through the Whitestone MARS model.
Installation Gas
6,463.76
,963.75
1
1
Plants for the production of oxygen, nitrogen, carbon dioxide, compressed air and other non-
8921
EA
U
heating gasses. Cost factors are based upon an average size of 1,500 SF with 100-HP
Production Plant
compressor. CCF is derived from USACE and Marshall & Swift data. SCF is derived using
the DoD developed template data for FAC 8910 and RS Means data.
Installation Gas
,990.00
||content||
,110.00
6
1
A facility for the storage of oxygen, nitrogen, carbon dioxide, compressed air and other non-
8922
EA
U
heating gasses. Cost factors are based upon an average size facility of 1,297 SF. CCF is
Storage
derived from USACE data. SCF is derived from the DoD developed template data from
FAC 4412.
Vehicle Scales
,455.40
9.08
40
1
A facility for weighing vehicles and their loads in a roll-on/roll-off mode. CCF is derived
8923
EA
S
from Marshall & Swift data. SCF is derived from data provided by the NY State Dept. of
Weights & Measures and commercial scale maintenance companies.
Miscellaneous Pump
9,332.74
3.53
1
1
Miscellaneous liquid pumping stations that are not included in another Facility Analysis
8924
EA
U
Category. CCF is derived from USACE data. SCF is derived from RS Means data.
Station
Energy Management
2,333.16
,255.24
1
1
A system to monitor and control the distribution of primary utility services throughout the
8925
EA
U
installation. Included are sensors at various locations, a central control unit, and
and Control System
communication lines to connect the sensors to the control unit. CCF is derived from
Marshall & Swift data. SCF is derived from Whitestone data.
45
DOD FACILITIES PRICING GUIDE Version 7