Assistant Officer in Charge (AOIC). Reports directly to the
Officer in Charge. This space may not be required within all facilities
since this person may already have adequate office space elsewhere.
Brief/Debrief Room. The debriefing room is used to instruct the
trainees in the training mission prior to the simulated flight and to debrief
the trainee on performance and improvement. This instruction incorporates
the use of charts and replay of the mission from the simulator computer
memory or tapes.
Accommodate two to eight people and a debriefing computer console
where required by the TFR. Access flooring is required for consoles. A CRT
screen, keyboard, and disk or tape drive unit cabinet are utilized. Provide
chart pin-up wall space and a marker board where required. One room at 100
square feet is required for each WTT or OFT. Maintain a maximum noise level
of 35 Dba complying with DM 1.03, Architectural Acoustics.
Classroom Equipment Storage. Provide a lockable closet accessible
from the classroom. Centralize other storage shared by other classrooms on
the same floor.
Computer Room. Generally contains the visual image generation
equipment, simulation computers, computer memory and peripherals, and
freestanding cooling equipment. This space is subject to modifications
whenever the training device is upgraded. Avoid other functions in computer
loads.
A typical OFT requires computer equipment area, work space and
equipment. The required access floor is typically 18 inches in height and,
if possible, depress the concrete subfloor 18 inches so the top of the
access floor is the same height as the facility finish floor adjacent to the
room. The access floor space will usually serve as a supply air plenum.
Conference Room. Address all types of conference space utilization
to ascertain needs. Accommodate flexibility in occupancy counts and table
arrangements. Consider providing the capability of subdividing the room(s)
with accordion folding partitions having a Sound Transmission Class (STC)
rating not less than 40 and provide maximum sound absorption in finishes.
Provide porcelain "marker board," bulletin board, and pull down projection
screen. Provide two means of egress with door swings in the direction of
exit travel for rooms exceeding an occupancy of 50 people.
Contracting Officer's Technical Representative (COTR) Office. The
COTR monitors contractor performance and serves as the primary point of
contact between the contractor and the Government. The COTR requires
administrative office space in close proximity but separate from the
contractor. Provide lockable private office for Government
representative(s). COTR's require efficient access to a variety of spaces in
the facility including the high bay, contractor offices and library.
Contractor Conference.
Ready access to a conference room large
enough for the contractor to meet in private with all personnel is required.
9