97
3.14.2.2 OMS/AMSA/DS/GS/Warehouse Uninhabited Spaces
AMSA workbay Mechanical Tools and parts storage Storage room
Battery room Supply room Unheated storage Warehouse area
3.14.3 The AT/FP criteria require a minimum standoff distance from
property lines to inhabited structures, and to primary gathering
structures. Uncontrolled parking and roadways also require
minimum setbacks from primary gathering areas, and from inhabited
structures or areas.
3.14.4 If the minimum standoff distances for the entire building or
facility cannot be provided due to site constraints, the uninhabited
spaces listed above may be located within the standoff distance.
The inhabited and primary gathering spaces must be kept outside
the standoff; if this is not possible, the building must be designed to
withstand a blast in accordance with the criteria.
3.14.5 Trash containers must be kept a minimum distance from
inhabited structures, and from primary gathering areas. This includes
trash containers serving the kitchen area; they must be a minimum
distance from the assembly hall.
3.15
Accessibility
3.15.1 All building entrances and POV areas should be accessible
to accommodate visitors and civilian employees.
3.15.2 Provide accessible parking spaces in accordance with
ADA-AG and UFAS.
3.16
Environmental
3.16.1 Noncontaminated Site Issues
3.16.1.1 Wetlands
3.16.1.1.1 The site topographic survey should include delineation
and survey the limits of wetlands identified on the site, if any. The
first consideration is to avoid wetland areas and to direct on-site
drainage to storm water treatment or storage ponds prior to
discharge into wetlands. In addition to meeting Federal regulations
regarding wetlands, it is recommended that designer coordinate with
State and local agencies with water resource/wetland jurisdiction.
The RSC and COE District Office should be consulted for points of
contact with such agencies.
UFC 4-171-05