MIL-HDBK-1027/4A
Table 2.6
TRAINER FACILITIES DATA-F/A-18 PTT
Non-motion devices
Room dimensions shown are minimums unless noted.
Model facility plates may show site specific larger dimensions.
** CAUTION: This document is for preliminary planning only.**
**Verify with NAWCTSD and NAVAIR prior to use. **
REFERENCE DOCUMENTS
General Requirements for Aviation Training Facilities, NAWCTSD Orlando
TRAINER FACILITY INFORMATION, NAWCTSD Orlando
Trainer Facilities Report for F/A-18 Part Task Trainer, HI 84-33/7002, 21
June 1984, Gould Inc., Systems and Simulation Division, 50 Marcus Drive,
Mellville, NY 11747
ARCHITECTURAL
SPACE NAME
MIN DIMENSIONS OCCUPANT
MAX NOISE
ACCESS REMARKS
(LxWxH)
COUNT
LEVEL
FLOOR
30'x 22'x 8'
Device/Trainee Area.
6
55Db(A)
12" h
1&2
Computer Area
3
Maintenance Area
3
General Notes:
Above requirements are PTT specific. See other data for administrative &
support spaces. Equipment noise is indicated on the Trainer Equipment
Summary.
Remarks:
1.
10' ceiling height preferred in this size room.
2.
72"w x 84"h hinged door required for equipment access.
3.
Space is included in Device/Trainee Area.
STRUCTURAL
Device transport method: 4 casters at 2 square inches each load bearing
surface.
Vibration Control: None required.
Permanent installation pads: 4 at 2.76 square inches each
54