MIL-HDBK-1027/4A
Table 3.4
TRAINER FACILITIES DATA-F/A-18 Environmental Control System Trainer
Room dimensions shown are minimums unless noted.
** CAUTION: This document is for preliminary planning only.**
**Verify with NAMTRAGRU Code N5 prior to use. **
REFERENCE DOCUMENTS
Technical Manual F18-NAMT-01 Volume 1, Environmental Control System Trainer,
74D090001-1001 and 74D090001-1003, McDonnell Aircraft.
ARCHITECTURAL
MIN DIMENSIONS
Device Operating Envelope
225.5"x 127"x 101.6"
panel 1
114.5"x 48.3"x 63.4"
panel 2
54"x 35"x 63"
panel 3
General Notes: Above requirements are Trainer Device specific.
See other data
for administrative & support spaces.
STRUCTURAL
Device installation transport method: casters
Device panel 1 operating weight = 5790 pounds, shipping weight = 6255 pounds.
Floor load for panel 1 in operating configuration with jack pads = 14.0 psi
Device panel 2 operating weight = 1295 pounds, shipping weight = 1635 pounds.
Floor load for panel 2 in operating configuration with jack pads = 6.5 psi
Device panel 3 operating weight = 565 pounds, shipping weight = 565 pounds.
Floor load for panel 3 in operating configuration with casters = 400 psi
90