MIL-HDBK-1032/2
Section 9:
Purpose. It is the intent to bring the existing semi-permanent and
9.1
permanent warehouse buildings to a level comparable with current standards for
new construction, in accordance with criteria in the appropriate Design
Manuals. Buildings selected for modernization shall be architecturally
acceptable and structurally sound. Existing low-rise buildings can be used
for support functions when located adjacent to new high-rise facilities.
Section 9 provides additional specific criteria applicable to modernization of
facilities.
General architectural requirements
Architectural Requirements.
9.2
include the following:
Floors. Install resilient floor tiles, with appropriate base, in
9.2.1
administration offices where the present floor surface is concrete. If the
present floor is wood, tiles, or linoleum, provide new tile only if the
existing floor is excessively worn and unattractive. Repair concrete floors
in storage areas if the surface is in poor condition.
9.2.2
unacceptable condition or of colors contrary to those prescribed by criteria
or according to use or occupancy. Such spaces shall be repainted in colors
complying with the NAVFAC Architecture Criteria Manuals and NAVFAC P-309.
Design For Handicapped. Perform modifications necessary to assure
9.2.3
access to the handicapped unless building use is specifically restricted to
able-bodied military personnel. Modifications shall be in accordance with
criteria in the NAVFAC Architecture Criteria Manuals, DOD 4270.1-M, and ANSI
Al17.1-1961 (R1980).
9.2.4
Roof. Inspect roofing and flashing for deterioration, cracks, and
wind damage. Repair or replace deteriorated, damaged, or missing flashing and
roofing. Install or increase insulation in accordance with requirements of
NAVFAC DM-3.03.
Doors And Windows. Inspect doors and windows. Replace broken glass
9.2.5
and repair or replace weatherstripping. If doors or windows are severely
deteriorated, investigate the economics of replacement with energy efficient
models.
Structural Requirements. When it is determined that the structural
9.3
system will not satisfy the design loads, those members which are considered
inadequate shall be strengthened, modified, or replaced.
Structural Systems. Structural systems should be inspected and,
9.3.1
where deficiencies are noted, the following shall be performed:
Clean off any corrosion and apply rust-resistant
Steel Members.
9.3.1.1
paint.
97