UFC 4-740-14
1 August 2002
7-2.1.7.3
Provide two child-height hand washing sinks mounted at 550 mm (22 in.)
above floor with a minimum 475 mm (19 in.) clearance for knee space. Install counters,
450 mm to 500 mm (18 in. to 20 in.) deep to allow children to reach controls.
7-2.1.7.4
Provide one drinking fountain.
7-2.1.7.5
Provide a minimum of two adult height sinks, one for diapering and one for
hand washing. Physically separate these two sinks to avoid cross-contamination.
7-2.1.7.6
Provide a minimum of one art sink.
The Air Force does not require
an art sink.
7-2.1.8
Preschooler activity area special plumbing fixture requirements.
7-2.1.8.1
Do not install floor-to-ceiling walls around the toilet area.
7-2.1.8.2
Provide a minimum of two water closets, with water closet seat height of
approximately 280 mm (11 in.), including seat. These toilet areas are used by both girls
and boys, and are partially screened but without doors. This offers some privacy, but
still allows adult supervision. Install partitions between the water closets that do not
exceed 1065 mm (42 in.) in height and are no more than 150 mm (6 in.) above the
finished floor.
7-2.1.8.3
Provide two child-height hand-washing sinks, mounted at 550 mm (22 in.)
above floor with a minimum 475 mm (19 in.) clearance for knee space. Install counters,
450 mm to 500 mm (18 in. to 20 in.) deep, that allow children to reach controls. Or use
junior-height wash fountains with a washbasin rim height of approximately 635 mm (25
in.).
7-2.1.8.4
Provide one drinking fountain.
7-2.1.8.5
Provide a minimum of two adult-height sinks, one for diapering and one for
hand washing. Physically separate these two sinks to avoid cross-contamination.
7-2.1.8.6
Provide a minimum of one art sink.
The Air Force does not require
an art sink.
7-2.1.9
Barrier Free Accessible Plumbing Design Requirements.
Design public/staff toilets to be barrier free accessible.
Include one barrier free accessible toilet for toddlers and preschoolers.
7-2.1.10
Laundry and Janitor Sinks. Provide a mop sink in the janitor's closet
and a laundry tub in the central laundry room. Use integral molded sinks rather than
drop-in sinks to prevent water infiltration into counter tops.