MIL-HDBK-1027/4A
TABLE 3.1 (Continued)
RECOMMENDED FINISHES-AVIATION MAINTENANCE TRAINING FACILITIES
General Notes:
1.
See Glossary for finish material abbreviations
2.
VWC and alkyd paint use is limited due to vapor infiltration.
Remarks:
1.
Alternate durable floors include concrete with hardener/sealer.
2.
Exposed and painted ceilings are also acceptable.
3.
Consider acoustical wall panels where additional sound absorption is
required.
4.
Metal slat ceilings are prohibited. Refer to paragraph 3.2.2.5 for
further data.
5.
Provide washable paint with eggshell or semigloss finish.
6.
Carpet is discouraged. Provide other methods of sound control.
7.
Consider alternate durable floors such as terrazzo.
8.
Consider functions and consult user to verify floor and ceiling
finishes.
9.
Provide washable and mildew resistant paint with gloss finish.
10.
Provide acoustical ceiling tile where sound absorption is needed. See
"Avionics Trainer" for special finishes.
11.
Provide a white color "dry shake" hardener.
70