UFC 4-211-01N
25 October 2004
doors must be rated as required.
3-22.4
Hardware. Choose hardware appropriate for the spaces served.
Special hardware includes:
3-22.4.1
Cipher locks on some spaces where security is required. Cipher
locks may be provided on the following spaces as required by the activity:
CO office
XO office
Operations
Secure Office
Ready Room
3-22.4.2
Keying must conform to the Base requirements including
removable cores. Generally, all squadron spaces should be keyed alike with
change keys for individual doors. The building should have a grand master key
system.
3-22.5
Windows and Glazing. Choose single pane glass set in metal
wrap around frames. Glass should be wire or tempered type as required by code
based on the opening rating. Use laminated glass for windows exposed by the
hangar bay. Thermal insulated glass should have a laminated glass pane on the
inside (occupied side) of the window assembly.
For openings in the wall between the Hangar and Maintenance
Control, provide fire-rated steel windows. Use wire glass or fire-rated glazing.
3-22.6
3-22.6.1
Floors
Administrative spaces Resilient tile or carpet as requested by the
activity.
Locker rooms Ceramic tile
Toilets Ceramic tile
Showers Ceramic tile
CO, XO suite Carpet
Officers Ready Room Carpet
20