MIL-HDBK-1037/8
i)
Special Requirements
(1) The minimum square footage requirement for
climbing wall can be determined as an 2438 mm(8-foot)
unobstructed safety zone that extends directly in front of all
climbing surfaces for the entire length of the wall. This
unobstructed safety zone will increase proportionally for
climbing features that overhang the belay anchor area.
(2) The flooring beneath the climbing wall should be
a soft and resilient surface. Surface such as recycled rubber
chips, a resilient rubber playground surface. The depth of the
material should be specified to attenuate a 3048 mm (10-foot)
fall.
(3) Belay system attachment hardware shall be
installed at the top of the climbing wall to allow for a top rope
belay configuration. Consider belay anchor bolts installed in
floor or on adjacent wall located a minimum of 2438 mm (8 feet)
from the climbing wall.
4.1.7
Room/Activity Name.
Indoor running track (optional).
a) Activity Description: A space for the development
and enhancement of aerobic activities; namely, running, jogging
and walking.
b) Hours of Use: Monday through Friday 0600-2200;
Saturday/Sunday/Holidays 0900-2000. Coordinate specific hours
with local command.
c) User Groups: Military personnel, family members,
reservists, retirees, and eligible DOD civilians.
d) Number of Users:
Daily average varies by base
population and programs.
e) Special Finishes Required: The track surface (over
the track foundation) should be a composite, synthetic material
engineered for running and walking. The surface material 9.5 mm
thick minimum (3/8 inch thick minimum) for the track should
provide a durable, resilient, and cushioned covering.
f) Utilities Requirements: The indoor running track
area should have an appropriate source and level of light. Metal
halide, mercury vapor, or fluorescent lights are recommended,
should be at least 300 lux to 500 lux (30 to 50 footcandles) at
the surface of the indoor running track.
g)
Furnishing, Built-in and Collateral Equipment List
25