MIL-HDBK-1037/8
(2) Provide a 34 kilogram (75-pound) kick bag with
adequate structural support.
(3)
Drinking fountain located adjacent to room
entrance.
(4)
Wall clock.
h) Adjacency Considerations: Provide easy access to
all patrons from entry and locker rooms, flexibility of
activities, good patron control and adequate storage area.
i) Special Requirements: The combative/martial arts
room must have a minimum of 500 lux (50 footcandles) of lighting.
Recommend natural lighting (skylights or windows) be used
whenever possible, being careful to avoid heat gain, harsh direct
sun lines and glare.
j) Space Size (square meter (feet), occupancy, or unit
of equipment): The combative/martial arts room must be a minimum
of 74.3 square meters (800 square feet).
4.1.5
Racquetball/Handball Courts
a) Activity Description: For the instructional,
informal and intramural patron and to maintain a high level of
physical fitness.
b) Hours of Use: To Be Used Daily. Monday through
Friday 0600-2200; Saturday/Sunday/Holidays 0900-2000. Coordinate
specific hours with local command.
c) User Groups: Military personnel, family members,
reservists, retirees, and eligible DOD civilians.
d) Number of Users: Daily average varies by base size
and number of courts available for play.
e)
(1) The floor should be a hardwood covering with a
sleeper system subsurface structure as in standard gymnasium
construction. Flooring systems require level subsurface systems
with vapor barriers. Provide expansion material along perimeter
of floor such as cork.
(2) Court walls and ceilings shall be constructed of
laminated high density wood composite panels or tempered
shatterproof glass. Provide vapor barrier at exterior wall(s)
and/or wet zones, e.g., showers, locker rooms, swimming pools.
21