MIL-HDBK-1037/8
4.1.4
Combative/Martial Arts Room (Optional)
a) Activity Description: To be utilized for the
instruction and practice sessions of combative and martial arts
disciplines. The martial arts program can be included in the
aerobics room; however, additional storage capacity is required
to contain martial arts exercise mats.
b) Hours of Use: Daily.
Times will vary.
Coordinate
specific hours with local command.
c) User Groups: Military personnel, family members,
reservists, retirees, and eligible DOD civilians. Approximately
75 percent utilization by military personnel and family members.
d) Number of Users:
Daily average varies by base
population and program.
e)
(1) The floor of the room should be hardwood with a
subsurface sleeper system or resilient materials to prolong the
life of the mats.
(2) At least one wall should be finished with
mirrors to a minimum height of 2133 mm (7 feet) above the
finished floor. The wall mirrors should be mounted continually
edge-to-edge, approximately 354 mm (1 foot 2 inches) above the
finished floor. Specify trim moldings along the top and bottom
edges of the mirrors, and along the mirror ends if they are not
flush with end walls.
(3) The remaining walls should be covered with
impact absorbent material; e.g., tatami mat up to 1524 m (5 feet)
above the finished floor on all sides.
(4) The ceiling must be of acoustic material and a
minimum of 3657 mm (12 feet) high.
f)
Utilities Requirements
(1) Light controls should allow for variable
lighting levels rheostat.
(2)
Provide special outlets for phone jacks.
g)
Furnishing, Built-in and Collateral Equipment List
(1)
Storage space for exercise mats and equipment
20