MIL-HDBK-1037/8
(1) The control area or administrative area shall
have a floor-to-writing-surface height of 1062 mm (42 inches) on
the patron side of the control counter. Consider overhead
storage located above the counter.
(2) Sufficient space must be provided at the control
desk for cabinets, computers, cash register and other necessary
operating equipment if the area is separate from the
administrative spaces.
f)
Utilities Requirements
computers, copy machine, PA system, and phone jacks.
(2) Provide controls at the counter for the facility
monitor, and AV controls, located throughout the complex.
(3)
If vending is provided as another over-the-
counter service,
provide necessary utilities to support the
requirement. If
collateral vending equipment is required for
over-the-counter
service, specify the correct counter heights,
cutouts, utility
requirements to support the equipment.
g)
Furnishing, Built-in and Collateral Equipment List
(1) Provide a bi-level control counter, low for
visual monitoring and high for completing paperwork/forms, and
have shelving/drawers underneath. Provide stand-up height for
patrons and desk height for staff use. The control desk shall
have space for optional vending equipment, bulletin boards,
chairs(s), waste receptacle, and a mobile laundry cart.
(2) Each individual administrative space must be
large enough to accommodate the following items: work desk with
chair, computer, filing cabinet, and guest chair. In addition,
provide general office space for community equipment, such as
receptacles. If a safe is required, provide a location for it in
a storage cabinet or closet.
h)
Adjacency Considerations
(1) The control desk shall be easily identifiable
and locatable upon entering the facility. The control counter
should be incorporated as an integral part of the lobby and as a
transition between the public and staff spaces. The control desk
should be adjacent and readily accessible to the administrative,
gear issue, laundry and staff spaces. Staff working at the
control desk shall be able to visually monitor the access points
34