MIL-HDBK-1037/8
(2) Large 1067 mm (42-inch) wide doors. Protect
doors and walls from impact by carts and the movement of
equipment. Recommend durable finishes and metal/high impact
plastic corner guards.
f)
Utilities Requirements
(1) The required lighting level is 500 lux
(50 footcandles).
nonbreakable, and moisture resistant with protective covers.
(3) Coordinate utility requirements and electrical
receptacles with a commercial grade washer and dryer extractor.
g)
Furnishing, Built-in and Collateral Equipment List
(1) The gear issue shall have adjustable shelving
and counters for storage and distribution of athletic gear and
recreation equipment.
(2) The laundry area must have the following types
of equipment: Washers (commercial grade) - 35- to 50-pound
capacity; dryers (commercial grade) - 50- to 120-pound capacity;
tables with integral shelf below, ice machine (locate adjacent to
utility sink and provide separate floor drain), storage bins, and
utility sink.
(3)
There shall be a minimum of two dryers per
washer.
h)
Adjacency Considerations
(1) The gear issue room shall be readily accessible
to activity and support spaces. The space shall be adjacent to
staff administration spaces and/or the control counter. This
space may function with the equipment and towels issued from the
control counter and stored in a separate but adjacent room.
(2) The laundry room shall be readily accessible to
the gear issue room, and adjacent to the staff administration
spaces.
i)
Special Requirements
(1) Coordinate door openings and dimensions with
room layout and equipment sizes, e.g., laundry carts, washers,
dryers, and ice machines.
36