206
F.2
Continued
F.2.2 Male Toilet Fixture Counts Peak Occupancy Water Closets Urinals
Lavatories Showers Total Fixtures Space
Peak
Water
Total
Occupancy
Closets
Urinals Lavatories Showers Fixtures
Space
1
to
35
2
1
2
1
6
200
SF
6
to
55
2
1
3
1
7
225
SF
6
to
60
3
1
3
1
8
250
SF
1
to
80
3
1
4
1
9
250
SF
1
to
90
3
2
4
1
10
300
SF
1
to
125
4
2
5
2
13
325
SF
26
to
150
4
2
6
2
14
350
SF
51
to
170
5
2
6
2
15
375
SF
71
to
190
5
2
7
2
16
400
SF
91
to
215
6
2
7
2
17
400
SF
16
to
230
6
2
8
2
19
450
SF
31
to
270
6
3
8
3
20
475
SF
71
to
305
7
3
9
3
22
500
SF
06
to
310
7
3
10
3
23
500
SF
11
to
350
8
3
10
4
25
575
SF
51
to
390
8
3
11
4
26
600
SF
91
to
395
9
4
11
4
28
625
SF
96
to
430
9
4
12
4
29
625
SF
31
to
440
10
4
12
5
31
675
SF
41
to
470
10
4
13
5
32
700
SF
71
to
485
10
5
13
5
33
700
SF
86
to
510
10
5
14
5
34
725
SF
11
to
530
11
5
14
5
35
750
SF
31
to
550
11
5
15
5
37
800
SF
51
to
575
12
5
15
6
38
800
SF
76
to
590
12
5
16
6
39
825
SF
91
to
620
12
6
16
7
40
850
SF
21
to
630
12
6
17
7
42
875
SF
31
to
665
13
6
17
7
43
900
SF
66
to
670
13
6
18
7
44
925
SF
71
to
710
14
6
18
7
45
950
SF
UFC 4-171-05