UFC 4-721-10
31 July 2002
Provide floor and wall finishes as described in Table 10-1. Use solid surfacing
material for lavatory counters and solid plastic, continuous anchorage toilet
partitions. Provide a floor drain placed out of the usual traffic pattern and close to
the water closets. Provide appropriate dispensers for soap, towels, toilet tissue,
and recessed waste receptacle. A single unisex toilet may be adequate for
smaller capacity bachelor housing.
3-17
HOUSEKEEPING/JANITORIAL. Requirements for Housekeeping
varies by Plan. Refer to the specific Plan's chapter for details.
3-18
ADMINISTRATIVE AREA (SPACE). Requirements for
Administrative areas (spaces) varies by Apartment, Room, and Module. Refer to
specific Plan chapter for details.
3-19
LOBBY, VESTIBULE, AND RECEPTION. Lobby, Vestibule, and
Reception vary by Plan. Refer to the specific plan chapter for details.
3-20
TELEPHONES. Provide a structured voice telecommunications
cabling system including fiber optic or Category 5e copper cabling from the base
telecommunications system to the room wall outlet. Provide dedicated
telecommunications equipment rooms, backbone, horizontal, and campus media
and raceway systems as required by the following industry standards:
EIA TIA/EIA-570-A, Residential Telecommunications Cabling
Standard;
EIA TIA-758, Customer-Owned Outside Cable Plant
Telecommunications Cabling Standard;
EIA TIA/EIA-569-A, Commercial Building Standard for
Telecommunications Pathways and Spaces;
EIA TIA/EIA-568-A-5, Transmission Performance Specifications for
4-Pair 100 Ohm Category 5e Cabling Addendum No. 5 to TIA/EIA-
568-A;
EIA TIA/EIA-568-B.2, Commercial Building Telecommunications
Standard Part 2: Balanced Twisted-Pair Cabling Components
Revision of TIA/EIA-568-A; and
EIA TIA/EIA-568-B.3, Optical Fiber Cabling Components Standard.
Provide government owned outside plant media and raceway in
accordance with EIA/TIA 758.
3-20.1
In-Room Telephone Services. Provide In-Room Telephone
services for each resident per the assigned Plan design. Provide one dedicated
line to two separate outlets on opposite walls. Locate one outlet on each party
3-4