212
I-2
I.2.1 Due to the variety of functional areas possible and variance in the
Space Design
medical equipment, the Using Service will provide a list of equipment and
Information
proposed locations for any special requirements when the concept design is
completed.
I.2.2 Refer to the space design information for office and administrative
spaces in Chapter 4 as a guideline for systems, furniture, equipment, and
finishes. Review recommended selections with Tenants, and obtain their
input. Finishes should be those appropriate to a civilian medical clinic with
I.2.3 The necessary medical equipment, standard medical equipment sets
including X-ray machines, will be provided and installed by the Tenants. An
X-ray equipment installation certificate will be required. Other furniture and
equipment is to be addressed as for the remainder of the training center.
I.2.4 Built-in equipment may include the following:
I.2.4.1 Waiting room: Admissions counter 400 mm (15 in) wide by
250 mm (49 in) high by 3650 mm (12 ft) long. A portion should be
accessible.
I.2.4.2 Dressing room: Feed-in clothes hooks - four per dressing
room. A seat may be built in on one side.
I.2.4.3 Medical exam room: Wall hung lavatory, or sink in cabinetry.
I.2.4.4 Dental exam room: Wall hung lavatory, or sink in cabinetry.
I.2.4.5 Laboratory: Base cabinets 610 mm (24 in) deep by 915 (36
in) high with chemical-resistant work counter and a two-compartment
stainless steel sink. This unit will be located on one wall or as an
island. The total length should not exceed 4900 mm (16 ft).
I.2.4.6 Specimen toilet: One water closet, one lavatory, one shelf, one
towel dispenser and one pass-through door to the laboratory.
I.2.4.7 Dark room: Work counter 610 mm (24 in) wide by 915 mm
(36 in) high by 2450 mm (96 in) long with chemical-resistant work
surface. This may be located on a wall and/or an island.
I.2.4.8 Audio/meter room: One booth 915 mm (3 ft) by 1525 mm (5
ft) with sound treatment to 55 STC and one counter on one end of
the room, 460 mm (18 in) wide and 715 mm (28 in) above the floor.
I.2 Space Design Information The Tenants may provide a portable
booth in lieu of a constructed room.
UFC 4-171-05