UFC 4-740-14
1 August 2002
C-2.3 Large CDC.
1.
Food delivery utility carts (NSF
approved or equivalent standards),
with three shelves (minimum shelf size
18 in. 26 in.) and overall maximum
height of 34 in.
2.
Stainless steel wall shelf over food
delivery utility carts (12 in. deep)
3.
Trash receptacle (minimum 44 gallons)
on mobile trash receptacle dollie
4.
Fire protection system panel
5.
Stationary shelving units (NSF
approved or equivalent standards) for
dry storage
6.
Hand sink, wall mounted with support
brackets
7.
Mobile, stainless steel slicer stand
8.
Slicer (NSF approved or equivalent
standards)
9.
"L" shaped food preparation stainless
steel work table with turned-up rolled
rim edges, 6 in. high back splash, drain
boards, work sinks, drain board
mounted cone for garbage disposal
and vacuum breaker
10. Garbage disposal, control panel and
back splash mounted pre-rinse
11. "L" shaped stainless steel wall shelf
over prep work sinks and drain board
12. Reach-in refrigerator, two door (46
cubic feet minimum) for prepared
snacks
13. Mobile stainless snack work table with
utensil drawer, undershelf and locking
casters
14. Mobile, stainless mixer stand
15. Mixer, 20 quart, bench model (NSF approved or equivalent standards)
16. Cook's island stainless steel work table with counter work sink, utensil drawer, undershelf, double sided over
shelf
17. Ceiling mounted pot rack
18. Bulk milk dispenser with four 6 gallon single service containers, NSF approved or equivalent standards
(optional, not shown on drawing)
19. Shelving unit (NSF approved or equivalent standards) for serving dishes
20. Single selection, dual temperature reach-in refrigerator/freezer with two half length doors (each section 9
cubic feet minimum)
21. Stainless steel work table with cross bracing on back and sides
22. Mobile food warmer with universal rack slides and maximum height of 34 in. (NSF approved or equivalent
standards)
23. Stainless steel shelf over cook's work table for spices, utensils and miscellaneous items
24. Exhaust hood, low volume high velocity (remote makeup air, if necessary)
25. Fire protection system, either water mist or wet chemical agent
C-8