115
Cooling, occupied 25 degrees C (78 F); maintained
ambient
Ventilation comply with ASHRAE 62
Electrical
Lighting 50 fc; dual-level switching
Voice/data two voice/data duplexes per wall
||content||
\ Furniture
Folding tables and chairs, or fold-up tables with attached
stools or attached benches
Mobile floor lectern
Adjustable stool with or without arms
Equipment
Public address system with speakers and microphone
outlets contractor-supplied
Ordinary hazard sprinklers
White boards and projection screens may be added if
Tenants desire
Special features or considerations
Typically must be separated from adjacent spaces with
rated wall
If the ceiling is not suspended acoustical tile, the acoustics
of the room must be addressed
If operable partition is included, provide structural support
and stacking space
If fold-up tables with attached stools or benches are
provided, ensure that the door to chair storage is
tall enough to accommodate the height of these
items folded into their mobile configuration
If fold-up tables with attached stools or benches are
provided, provide a few folding tables and stacking
chairs to be used as registration tables, banquet
tables, etc. also provide table dollies and chair
caddies for these items. /1/
4.2.9 Chair and Table Storage
4.2.9.1 This space is for the storage of the assembly hall tables and
chairs when not in use. The PA system for the assembly hall is also
typically located here.
||content||
\ The PA system shall have wireless clip-on
type microphones. /1/
4.2.9.2 This space should not be used for mechanical equipment or
electrical panels due to the potential for damage to them or
obstruction by the stored furniture.
UFC 4-171-05