116
4.2.9.3 Space Design Information
General/Code
Size 10% times assembly hall authorized area
Occupancy business
Occupancy count 1 person per 9.3 sq m (100 sf)
Architectural/Interiors
Minimum STC rating 40
Ceiling height 3000 mm (10 ft)
Floor sealed concrete
Base rubber
Walls painted gyp board; painted CMU as alternative
Ceiling suspended acoustical ceiling tile (ACT)
Trim wall guard to protect walls
Lockset storeroom on active leaf; flush bolts inactive
Mechanical
Heating, occupied 20 degrees C (68 F); maintained 13
degrees C (55 F)
Cooling, occupied none; maintained none
Ventilation comply with ASHRAE 62
Electrical
Lighting 10 fc
for PA
Voice/data none
||content||
\ Furniture
Table caddies for assembly hall folding tables
Chair dollies for assembly hall stacking chairs
Storage cabinet for PA system for Assembly Hall
Equipment
PA system for Assembly Hall with amplifier and minimum
of two (2) or three (3) wireless clip-on type
microphones
Special features or considerations
Conduit to roof-mounted AM/FM antenna may be desired
voice/data outlet for office
If fold-up tables with attached stools or benches are
provided, ensure that the door into chair storage is
tall enough to accommodate the height of these
items folded into their mobile configuration /1/
4.2.10 Kitchen (See Also Appendix E)
4.2.10.1 The kitchen module provides space for training of cooks,
and for preparation of meals. It includes space for food preparation,
cooking, serving and for the storage and cleaning of cookware and
serving ware, and is divided into four areas. It is strongly
recommended that designers of non-MDS projects request a copy
of the MDS standard kitchen drawings for reference.
UFC 4-171-05