109
Architectural/Interiors
Minimum STC rating 40
Ceiling height 2600 mm (8'- 8")
Floor VCT; carpet as an alternative
Base rubber Walls painted gyp board
Ceiling suspended acoustical ceiling tile (ACT)
Trim Lockset office
Mechanical
Heating, occupied 20 degrees C (68 F); maintained
13 degrees C (55 F)
Cooling, occupied 25 degrees C (78 F); maintained
ambient
Ventilation comply with ASHRAE 62
Electrical
Lighting 50 fc; dual-level switching
height
Voice/data telephone and data outlets
||content||
\ Furniture
There is no furniture provided for this room function/1/
Equipment
Verify if postage or other machines require power
Upper and lower cabinets with counters for work
space and storage
Special features or considerations
Mail slots may require fire doors if they open into a
corridor Some units locate a large copier in this
space
4.2.6.2 Reproduction
4.2.6.2.1 This space provides for the reproduction and
collating of administrative correspondence, bulletins, orders,
and similar paperwork. The space may also house hard copy
printers connected to computers in the office space or to the
LAN. Diazo or blueprint reproduction is not typically included
in this space.
4.2.6.2.2 The reproduction space should be located adjacent
to the administration space. The space must be large enough
to accommodate the Tenants' copiers, and have table or
counter space for collating and binding. Sufficient storage
space should be provided for operating quantities of paper,
toner, ink, office supplies, forms, etc. The size of this area will
be relative to the size of the unit and specific reproduction
requirements.
UFC 4-171-05