141
Base rubber
Walls painted gyp board; paneling or vinyl as an
alternative
Ceiling suspended acoustical ceiling tile (ACT)
Trim chair rail
Lockset classroom
Mechanical
Heating, occupied 20 degrees C (68 F); maintained
13 degrees C (55 F)
Cooling, occupied 25 degrees C (78 F); maintained
ambient
Ventilation comply with ASHRAE 62
Electrical
Lighting 50 fc with dual-level switching; provide dimmers
Voice/data voice/data duplex on each wall
||content||
\ Furniture
Large wood conference table; small wood conference tables
optional
High-back upholstered chairs with adjustable seat height,
fixed arms, and swivel base at conference table
Sled-based chairs around perimeter of room
Full-height floor lectern with microphone and light
Adjustable stool with or without arms optional
Credenza
Equipment
Powered projection screen wired to lectern to allow
computer screen to be projected
Electronic presentation "smart board" with printing
capabilities, enclosed
Two inch (2") map rail on one (1) wall
Map rail to include end stops and hanger clips
Verify with Tenants if CATV, LCD projection, video
teleconferencing, etc., are desired (TV and projector
by Tenants) ACSIM-AR approval is required
Special features or considerations
Optional built-in casework may be appropriate for storage
and counter space
Provide chair rail around entire room
Provide structural support for ceiling mounted projector
(projector to be provided by Tenant) /1/
4.2.35 Drafting Room
4.2.35.1 This space is used for manual or electronic drafting training
and operations, printing, and storage of drawings and media. In most
cases it should be set up for one manual and one CAD drafting
station. Designer should verify typical drafting practice with Tenants.
UFC 4-171-05