140
Trim
Lockset office
Mechanical
Heating, occupied 20 degrees C (68 F); maintained
13 degrees C (55 F)
Cooling, occupied 25 degrees C (78 F); maintained
ambient
Ventilation comply with ASHRAE 62
Electrical
Lighting 50 fc
counters
Voice/data wall phone above counter
Furniture
Verify with Tenants
Equipment
Soils testing equipment by the Tenants
Special features or considerations
Chemical-resistant counter space 2.4 m (8 ft) in length
Two-compartment, chemical-resistant stainless steel sink
Consider filtered return registers
4.2.34 Conference Room
4.2.34.1 This space is used for meetings by the Commanding General
and/or staff within the general office or headquarters, and is only
authorized if there is a General officer in one of the units. It should be
near, or in, the General's suite. A higher level of finishes may be
appropriate.
4.2.34.2 The conference room must be capable of accommodating
20 people, with good sight lines from all seats and sufficient space for
ease of circulation during meetings. If space allows, additional seating
can be provided along one or more walls of the room.
4.2.34.3
||content||
\ Space Design Information
General/Code
Size 55.7 sq m (600 sf)
Occupancy business
Occupancy count by number of seats, or 1 person per 1.4
sq m (15 sf)
Architectural/Interiors
Minimum STC rating 40
Ceiling height 2600 mm (8'- 8") minimum
Floor carpet; VCT as an alternative
UFC 4-171-05