144
4.2.36.4 Space Design Information
General/Code
Size varies
Occupancy business
Occupancy count 1 person per 9.3 sq m (100 sf)
Architectural/Interiors
Minimum STC rating 40
Ceiling height 2600 mm (8'- 8") minimum
Floor cushioned athletic-type flooring;
VCT as an alternative base rubber
Walls painted gyp board; painted CMU as an alternative
Ceiling suspended acoustical ceiling tile (ACT)
Trim
Lockset classroom
Mechanical
Heating, occupied 20 degrees C (68 F); maintained 13
degrees C (55 F)
Cooling, occupied 25 degrees C (78 F); maintained
ambient
Ventilation 10 L/S (20 cu ft per minute) per person
minimum; sufficient ventilation for rigorous activity
do not recirculate to other spaces
Electrical
Lighting 30 fc
equipment
Voice/data wall phone
/1/ Electrical outlet and cable connection for TV hookup
Furniture
The exercise equipment is provided as part of the furniture
package
||content||
\ Equipment
A matrix of equipment has been developed based on room
size. Contact Louisville District, Corps of Engineers
for latest information exercise equipment
requirements
Minimum of one (1) treadmill and one (1) recumbent bike
per each physical readiness room
Mirrors on at least one wall
High and low exercise bars, not on the mirrored wall
One (1) generic TV wall mount bracket
Special features or considerations
Verify if Tenants want CATV or data jacks
Provide support for mounting TV bracket /1/
UFC 4-171-05