123
accommodating up to 50.
Figure 4-16 Classroom
4.2.13.3 The larger classrooms can be subdivided with a quality
operable panel partition, with an STC rating of 48-52. Extend the
sound attenuation above the ceiling to eliminate flanking points. For
subdivided rooms, provide equipment for both sides of the partition.
Specifications for operable partition should include O & M manual,
and provision of multiple sets of any required operating hardware.
Figure 4-17 Classroom with Operable Partition
4.2.13.4 Room-darkening shades or blinds should be provided for
classrooms with windows.
4.2.13.5 Portions of any facility which serve a unit with more than 50
members, such as a school command, will be designed as educational
occupancies, and meet applicable code criteria for such occupancy.
The library, learning center, COMSEC training, and their support
spaces will be part of this educational occupancy area.
UFC 4-171-05