128
Equipment
Marker board with 2" map rail; map
rail to include end stops and
hangerclips
Powered projection screen wired to instructor's lectern to
allow instructor's computer screen to be projected
Special features or considerations
Power outlets and data outlets should be provided along the
wall at each table location for ease of access
If the room is lined with room dividers instead of hard walls,
floor outlets may be an option /1/
4.2.17 Training Aids Storage
4.2.17.1 This space is for the storage of teaching aids (including A/V
equipment), manuals, publications, and models. The designer should
verify the types of materials to be stored, and design the space
accordingly.
4.2.17.2
||content||
\ Space Design Information
General/Code
Size 10% times total classroom area authorization
Occupancy business
Occupancy count not occupied; typically 1 person per 300 sf
Architectural/Interiors
Minimum STC rating 40
Ceiling height 2600 mm (8'- 8")
Floor VCT
Base rubber Walls painted gyp board
Ceiling suspended acoustical ceiling tile (ACT)
Trim chair rail
Lockset storeroom Mechanical
Heating, occupied 13 degrees C (55 F); maintained 13
degrees C (55 F)
Cooling none
Ventilation incidental
Electrical
Lighting 30 fc
Voice/data wall phone
||content||
\ Furniture
Tables with c-legs on castors, wire management basket, sling
Table to be 9.14 m (30") deep and long enough to
accommodate 2 computers with three-ring binder space
between.
UFC 4-171-05