130
Ventilation comply with ASHRAE 62
Electrical
Lighting 50 fc; dual-level switching; provide additional
controls at whiteboard
Furniture
Folding tables and mid- or low-back task chairs
Bookcase
Table lectern
Equipment
Map rail, whiteboard, and powered projection screen
Special features or considerations
Consider incandescent downlights with dimmer to 15 fc for
room darkening
Provide room-darkening shades for windows
Verify if Tenants require CATV or permanent mount for LCD
projection (TV and projector would be Tenant-
provided)
Though not a requirement, Tenants normally prefer no
windows in this space
4.2.19 COMSEC Storage
4.2.19.1 This space provides storage area for sensitive communication
devices. However, a security safe may be substituted and placed within
a COMSEC training room. If a safe is utilized, then the room design
must provide sufficient space surrounding the safe for circulation and
door operation. The safe must be offset from the wall 12 inches in order
to open on two sides and swivel, thus requiring a slight increase in floor
space. Safes are provided by the Tenants, and weigh approximately
100 psf.
4.2.19.2 The door to a COMSEC storage room must be solid-core
wood or hollow metal industrial, lockable and without glazing. The
strike plate must be heavy-duty, high-security, and hinge screw length
must be sufficient to resist removal by prying. Hinge pins must be within
the space, or non-removable. An electro-mechanical lock meeting
Federal Specification FF-L-2740 is required.
4.2.19.3 If a storage safe is not incorporated into the COMSEC
training room, then the Storage room space must be secure against
surreptitious entry; provide gypsum board walls from floor to ceiling,
and a gypsum board ceiling, to provide visual evidence of any
attempted entry.
UFC 4-171-05