4.2.19.4 Air vents, ducts and similar openings that breach the room
envelope must be secured to prevent penetration; if greater than 2,000 sq
mm (96 sq in), provide hardened steel bar grates or IDS supervision. All
openings must be baffled to limit audio or acoustical transmission to non-
COMSEC spaces.
4.2.19.5 Space Design Information
General/Code Size varies Occupancy business Occupancy count
not occupied, typically 1 person per 300 sf
Architectural/Interiors Minimum STC rating 40 Ceiling height 2600
mm (8'- 8") Floor VCT Base rubber Walls painted gyp board
Ceiling painted gyp board Trim Lockset storeroom
Mechanical Heating, occupied 20
degrees C
(68 F); maintained 3
degrees C (55 F) Cooling none Ventilation incidental
Electrical Lighting 30 fc
Receptacles convenience
duplex Voice/data
wall phone
Furniture Verify with Tenants
Equipment Any safe(s) will be provided by with the Tenants Open
shelving
Special features or considerations Ordinary hazard sprinklers Though
not a requirement, Tenants normally prefer no windows in this space
4.2.20 Unit/Individual Storage
4.2.20.1 This space permits storage and inventory management of
organizational equipment, such as clothing, tents, radios, tool sets, etc., in
a separate and secure area. The issue and return of organizational
equipment is also conducted here, or in the staging area.
4.2.20.2 The unit storage space is typically subdivided into 2450 mm by
3675 mm (8 ft by 12 ft) cages constructed of woven welded wire fabric.
See Section 3.5.6 for additional information on cages and shelving. Aisles
and vestibules between the secured areas should allow for efficient
circulation and movement of stored equipment. Circulation space is not
included within the total area authorization.
UFC 4-171-05