UFGS CRITERIA - index
>
> 3_580_10
DESIGN: NAVY AND MARINE CORPS INTRANET (NMCI) STANDARD CONSTRUCTION PRACTICES
Record of Changes - 3_580_100002
FOREWORD - 3_580_100003
CONTENTS - 3_580_100004
CONTENTS-continued - 3_580_100005
FIGURES - 3_580_100006
TABLES-continued - 3_580_100007
CHAPTER 1. INTRODUCTION - 3_580_100008
ORDER OF PRESENTATION
CHAPTER 2. GENERAL CONDITIONS NEW CONSTRUCTION
Figure 2-1 NMCI Network Architecture (Simplified)
Entrance Facility (EF)
Location - 3_580_100013
Electrical - 3_580_100014
DISTRIBUTION LAYER
Telecommunication Rooms (TR)
Size of NMCI Equipment within TRs
Figure 2-2 Wall-Mounted or Floor mounted Cabinet
OUTSIDE CABLE PLANT
INSIDE CABLE PLANT - 3_580_100020
Cable
Interference Considerations
CLASSIFIED NETWORK REQUIREMENTS
CHAPTER 3. NMCI CONVERSION PROCESS
Coordination - 3_580_100025
Navy Facilities Engineering Commands
PHASE 1 PREPARATION
Preliminary Site Questionnaire
Initial Facilities Briefing
PHASE 2 -- JOINT ASSESSMENT/SURVEY
PHASE 3 DETAILED SURVEY AND DESIGN
Detailed Design
PHASE 5 COMPLETION
CHAPTER 4. SPECIAL CONSIDERATIONS DURING THE CONVERSION PROCESS
INSIDE CABLE PLANT - 3_580_100035
Wall Jacks and Cable
INTERIOR FACILITIES
Note - 3_580_100038
APPENDIX A. REFERENCES - 3_580_100039
APPENDIX A. REFERENCES-continued - 3_580_100040
APPENDIX A. REFERENCES-continued - 3_580_100041
APPENDIX B. GLOSSARY - 3_580_100042
APPENDIX B. GLOSSARY-continued - 3_580_100043
APPENDIX B. GLOSSARY-continued - 3_580_100044
APPENDIX B. GLOSSARY-continued - 3_580_100045
APPENDIX B. GLOSSARY-continued - 3_580_100046
Figure B-1 Single Line Drawing of EIA/TIA Facility/Function Terminology
APPENDIX C. SUPPLEMENTARY TECHNICAL GUIDANCE
TABLE C-1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS AND MINIMUM CONCENTRATED LIVE LOADS
TABLE C-2. NMCI MINIMUM LOADS
Figure C-1 Scope of TIA-J-STD-607 for Large Commercial Buildings
These Notes are in reference to Figure C-1
Figure C-2 Non TIA-J-STD-607 Compliant Building
MECHANICAL - 3_580_100054
Design Conditions - 3_580_100055
Design Conditions-continued
APPENDIX D. ELECTRICAL REQUIREMENTS
APPENDIX D. ELECTRICAL REQUIREMENTS-continued
Table D-1 -- Point of Presence (POP)
DPOP 5 & 6 Redundant Medium Base - (251 to 449 Seats)
DPOP 3 & 7 Redundant Small Base_2 (86 to 250 Seats)
DPOP 19 & 20- Redundant Small Base (34 To 85 Seats)
DPOP 24 & 25 Redundant Small Base -EXT. UPS-One -2 Ton A/C Alternate
DPOP 11-Redundant Small Site (1 to 33 Seats) [Two 1-Ton A/C units - Preferred]- EXT. UPS
DPOP 18- NON REDUNDANT SMALL BASE (SEATS 17-85) [Two 1-Ton A/C units]
Cabinet 'WPOP10'(SEAT COUNT LESS THAN 24)
DHTB1& DHTB2 TRANSPORT BOUNDARY CABINETS - EXT UPS-(Two - 3 Ton A/C units)
DPOP17 SERVER CABINET 2 (1701 to 5000 Seats) [One 2-Ton A/C unit ]
Table D-2 Main Cross Connect
Main Cross Connect - With Cooling Equipment
Table D-3 Intermediate Cross-Connect
Table D-3 Intermediate Cross-Connect-continued
Intermediate Cross Connect - Without Cooling Equipment-continued
Intermediate Cross Connect - With Cooling Equipment
Intermediate Cross Connect - With Cooling Equipment-continued
Figure D-1 Typical One-Line Diagram for Facility POPs
Figure D-2 Typical One-Line Diagram for Facility MC's/IC's
APPENDIX E. PROTECTED DISTRIBUTION SYSTEMS
Walls, Floor and Roof
Secure Room (SR)
Figure E-1 PDS DESIGN/APPROVAL PROCESS
PDS DESIGN/APPROVAL SUB-PROCESS "A"
PDS DESIGN/APPROVAL SUB-PROCESS "B"
3_580_10